  • ER2000测量接收机.jpg
  • 1(1709723452711).png
  • 2 (1).jpg
  • 2 (2).jpg
  • 2 (4).jpg
  • 2 (5).jpg

ER2000


Frequency range: 1kHz ~ 2GHz; Resolution bandwidth: 1Hz ~ 3MHz (-3DB), 200Hz/9KHz/120kHz/1MHz (-6DB); Comply with the CISPR 16-1-1 standard, including CISPR-AVG, CISPR-RMS, QPK detector; EMI receiver and spectrum analyzer two -in -one; The whole digital detector measurement is reliable and stable; Double RF input protection to ensure measurement safety; Rich test options meet different applications and measurements; Support ETR measurement analysis software;

Product Classification:

Key words:


The EMI measurement receiver complies with the CISPR16-1-1 standard and integrates CISPR-AVG, CISPR-RMS, QPK detector. Electromagnetic interference measurement is performed according to the standards of CISPR, EN, FCC, and MIL. EMC test in electronics, medical care and other industries. Combining ETR upper machine measurement software and rich testing options, accurate automation testing can be performed. The entire system standard spectrum analysis module and tracking signal generator can meet the test needs of users in different fields.

Embedded multiple EMI measurement standards

Embedded GB/GJB/EN/CISPR/FCC and other various EMI measurement standards to support custom standards.

EMI receiver and spectrum analyzer two-in-one

Dual system mode: EMI receiver and spectrum analyzer mode freely switch measurement.

Multiple detection methods

Peak PK, quasi -peak QP, average AV and other detection methods.

Built-in LISN and common differential mode separators

The output port of the LISN and the differences of the common mode can be switched to the output.

EMC automatic test system can be formed

Edit EMC measurement analysis and measurement software and remote control interfaces. The EMC automatic testing system can be set up to output test reports.

  • Frequency range: 1kHz ~ 2GHz
  • Reading accuracy: ± (frequency currency read number × frequency benchmark accuracy + half of the last display unit)
  • Resolution bandwidth range: 200Hz/9kHz/120kHz/1MHz
  • Resolution bandwidth accuracy: <10%
  • Robe: Zhengfeng, negative peak, quasi -peak, average, RMS
  • Scanning time: 100US ~ 100S
  • Scanning points: 301 ~ 1001
  • Number of trace lines: 3 (parallel detection waves)
  • List of frequency bands: 10
  • Frequency response: ± 2.0db
Model Name

EMI receiving

frequency range

Uncertainty in amplitude

measurement

                 Detector                  Scan time Spectrum frequency range Trace Source Price
ER300 1kHz~300MHz ±2.0dB Zhengfeng, negative peak, quasi -peak, average, RMS 100us~100S 1kHz~3.6GHz 100kHz~1.5GHz Quote
ER2000 1kHz~2GHz ±2.0dB Zhengfeng, negative peak, quasi -peak, average, RMS 100us~100S 1kHz~3.6GHz 100kHz~1.5GHz Quote
ER3600 1kHz~3.6GHz ±2.0dB Zhengfeng, negative peak, quasi -peak, average, RMS 100us~100S 1kHz~3.6GHz 100kHz~1.5GHz Quote
Configuration Describe Order number
Host EMI measurement receiver(1kHz~300MHz) ER300
EMI measurement receiver(1kHz~2GHz) ER2000
EEMI measurement receiver(1kHz~3.6GHz) ER3600
Standard CD (user manual, programming manual)  
Power line(220VAC)  
N/SMA-JK joint  
N/BNC-JK joint  
Built-in tracking source(100kHz~1.5GHz)  
Optional Artificial power network LSN016
Coupling down coupling network-M3 CDN016
Pulse limitation PLA030
Radio frequency switch RFS003
Current injection probe PRBI-400
Current detection probe PRB330
Probe calibration fixture CLA001
EMC test software BL.EMC.ETR

Previous Page

Next Page

Previous Page

Next Page

Universal attachments (optional)

Vector Net Calibration Kit

Sagittal Net Calibration Kit (4 SAM type negative calibration pieces, DC-9GHz)

Ultra short wave handheld direction finding antenna (9kHz~8000MHz)

9KHz-30MHz handheld directional antenna 20MHz~200MHz handheld directional antenna 200MHz~500MHz handheld directional antenna 500MHz~8000MHz handheld directional antenna

LNA010 broadband amplifier

When not using a direct power cord, it is necessary to ensure that the input voltage of the broadband amplifier is+5V. When using a direct power cord, it is necessary to ensure that the input voltage of the direct power cord is+5V

PLA030 Pulse limiter

The main function of a limiter is to limit the output signal amplitude to a certain range, which means that when the input amplitude exceeds a certain reference value, the output amplitude will be limited to a certain amplitude and will no longer change with the input voltage. The applicable frequency range is 50kHz~1GHz.

RFS003 Radio frequency switch

The applicable frequency range of the RF switch (RFS003) is 9kHz~300MHz. When the RF switch is turned off, the isolation degree is 34dB (minimum value). This RF switch is mainly used in conjunction with our company's limiter.

ANT01 Near-field probe

ANT01 is a cost-effective near-field probe primarily used to locate interference sources and determine the cause of interference. It can be used to detect the direction and strength of the magnetic field on the surface of the device;

PRBI-400 Current injection probe

The current injection probe is mainly used for conducting sensitivity measurement; The interference signal is injected into the signal cable or power line of EUT to simulate external interference to determine the conduction sensitivity of EUT.

CDN016-M3 Coupling decoupling network

The coupling/decoupling  network consists of two parts: coupling and decoupling.The main  function of decoupling is to prevent useful signals from leaking to the power supply terminal (AE port) and to prevent disturbing signals from interfering with useful signals. The function of coupling is to transmit the disturbance signal of the device under test (EUT port) to the signal port.(RF port) in order to measure by measuring instruments, or transmit the electromagnetic disturbance signal of RF transmitter to the tested equipment. 

VB30 vswr bridge

• Frequencyrange: 10MHz-3.6GHz  • Tested port: N (female) type  • IN-1o-DUTinsertion loss: 4dB (typical)  • Directionality: 24dB (typical)  • Maximum input power: +30dBm(lW)  • Applicable models: HSA800 series, SAi 000 series and SA2000 series 

T/R1000 RF Demo Kit

• Radio frequency amplifier: The frequency range is 10MHz~2GHz,And the gain is 9dB~15d8(14dB@lGHz) • Radio frequency band-pass filter: Bandwidth 920MHz沉5MHz,Center frequency 922.5MHz  • Mixer: RF IN 5MHz~1500MHz             LO IN 5MHz~500MHz             RF OUT DC-1000MHz  • Oscillator LO/N:Frequency range 35MHz~4400MHz, Output power -3dBm--10dBm  •Oscillator LO:The frequency range is 2200MHz~4400MHz.,And the output power is 0dBm~+ 13dBm • Variable gain amplifier:Frequency range 15MHz~30MHz, gainrange 0dB~30dB  • Intermediate band pass filter: Bandwidth19.9MHz~22.9MHz ,Center frequency 21.4MHz • Reference timebase: 10MHz  •Interfuce:USB

FD100 frequency detection characteristic test module

• Based on BALUELEC Spectrum Analyzer, It can provide frequency discrimination   characteristic test function, Which can replace frequency scrumer  • Size 100mmx60mmx25mm • Universal USB interfuce for easy control  • Weight≤200g • Applicable models: SA1000 series and SA2000 series

DA800 directional broadband antenna

• Frequency measurement range: 600MHz-8000MHz •Input impedance: 50Ω • VSWR(Typical):<2:1 • Gain (Typical): 6dBi • Weight: 400g • Dimension: 353mrnx223mrnx28mrn

Message feedback

Welcome to leave a message online, please fill in the information according to the following form; We will contact you as soon as possible according to the information you fill in

Submit Message

Contact Us

Tel: +86-0551-68107097

Email: admin@baluelec.com

Address: No. 800, Wangjiang West Road, High-tech Zone, Hefei City, Anhui Province China.

WeChat
WeChat
Tiktok
Tiktok
Video Number
Video Number

Copyright © Baluelec

安安新材料

 Powered by: 300.cn  |  SEO   |   Business License