SA1030C


Frequency range: 9kHz ~ 3.6GHz; The resolution bandwidth is 1Hz ~ 3MHz, the noise level is better than -158dBm; Patent dual source function, tracking source/independent source to switch [patent type: invention patent, patent number: zl 2012 1 0048337.7]; Special transient wave, quickly capture the transient signal; Waterfall maps, frequency counting, audio demodulation and other conventional and extended functions; Field strong measurement, frequency test testing, S11 and S21, channel measurement and other professional options; PASS-FAIL and other on-site detection alarm capabilities; 8 -inch highlights, multi -line computing measurement;

Product Classification:

Key words:


The SA1000 series portable spectrum analysis instrument shell uses ABS mold, portable lightweight, full digital intermediate frequency and embedded integrated control system to ensure its excellent performance and stable performance. Users can easily own. Rich and friendly man -machine interface, Chinese and English bilingual menu, simple operation, easy to learn and easy to use, making the test world more convenient and pleasant.

Universal spectrum analysis function

The general spectrum analysis complete parameters such as the frequency and power of the signal through the two measurement methods of scanning and FFT.

Advanced measurement function

There are measurement functions such as strong measurement, frequency counting, channel measurement, third-order interoperability, harmonic distortion, noise ratio, frequency counting, chromatography, audio demodulation and PASS-FAIL.

Express the average noise level

Ensure the ability to measure faint signals.

Patented dual source function

Follow the source/independent source to switch.

  • Frequency range: 9kHz ~ 3.6GHz
  • Resolution bandwidth: 1Hz ~ 3MHz
  • Phase noise: -90dBc/hz@30kHz
  • Show the average noise level: -158dBm
  • Scanning time is non -zero -scan width: 3ms to 3000s
  • Scanning time Zero -width: 1ms to 3000s
  • Scan mode: continuous, single, a single time
  • Trigger source: freedom, video, external
  • Power consumption of the whole machine: maximum 20W
Model Name Frequency range Maximum real-time bandwidth Resolution Bandwidth Phase noise Display average noise level Trace Source Price
SA1010B 9kHz~1.8GHz / 1Hz~3MHz -90dBc/Hz@30kHz -158dBm Optional Quote
SA1030B 9kHz~3GHz / 1Hz~3MHz -90dBc/Hz@30kHz -158dBm Optional Quote
SA1030C 9kHz~3.6GHz / 1Hz~3MHz -90dBc/Hz@30kHz -158dBm Optional Quote
Configuration Designation Model
Spectrometer host 9kHz to 1.8GHz SA1010B
9kHz to 3.0GHz SA1030B
9kHz to 3.6GHz SA1030C
Standard CD-ROM (user manual, programming manual)  
Power Cable (AC input)  
Optional 100kHz to 1.5GHz tracking source SA1030B-TG15
100kHz to 1.8GHz tracking signal source SA1010B-TG18
100kHz to 3.0GHz tracking signal source SA1030B-TG30
100kHz to 3.6GHz tracking signal source SA1030C-TG36
Field strong measurement SA1000-FS
Near -field probe kit ANT01
Frequency feature test module FD100
Omnidirectional antenna/directional antenna 0A750/DA800
Stading Bobby Bridge VB30
USB power sensor UP60
RF demonstration kit TR1000

Previous Page

Next Page

Previous Page

Next Page

Universal attachments (optional)

Vector Net Calibration Kit

Sagittal Net Calibration Kit (4 SAM type negative calibration pieces, DC-9GHz)

Ultra short wave handheld direction finding antenna (9kHz~8000MHz)

9KHz-30MHz handheld directional antenna 20MHz~200MHz handheld directional antenna 200MHz~500MHz handheld directional antenna 500MHz~8000MHz handheld directional antenna

LNA010 broadband amplifier

When not using a direct power cord, it is necessary to ensure that the input voltage of the broadband amplifier is+5V. When using a direct power cord, it is necessary to ensure that the input voltage of the direct power cord is+5V

PLA030 Pulse limiter

The main function of a limiter is to limit the output signal amplitude to a certain range, which means that when the input amplitude exceeds a certain reference value, the output amplitude will be limited to a certain amplitude and will no longer change with the input voltage. The applicable frequency range is 50kHz~1GHz.

RFS003 Radio frequency switch

The applicable frequency range of the RF switch (RFS003) is 9kHz~300MHz. When the RF switch is turned off, the isolation degree is 34dB (minimum value). This RF switch is mainly used in conjunction with our company's limiter.

ANT01 Near-field probe

ANT01 is a cost-effective near-field probe primarily used to locate interference sources and determine the cause of interference. It can be used to detect the direction and strength of the magnetic field on the surface of the device;

PRBI-400 Current injection probe

The current injection probe is mainly used for conducting sensitivity measurement; The interference signal is injected into the signal cable or power line of EUT to simulate external interference to determine the conduction sensitivity of EUT.

CDN016-M3 Coupling decoupling network

The coupling/decoupling  network consists of two parts: coupling and decoupling.The main  function of decoupling is to prevent useful signals from leaking to the power supply terminal (AE port) and to prevent disturbing signals from interfering with useful signals. The function of coupling is to transmit the disturbance signal of the device under test (EUT port) to the signal port.(RF port) in order to measure by measuring instruments, or transmit the electromagnetic disturbance signal of RF transmitter to the tested equipment. 

VB30 vswr bridge

• Frequencyrange: 10MHz-3.6GHz  • Tested port: N (female) type  • IN-1o-DUTinsertion loss: 4dB (typical)  • Directionality: 24dB (typical)  • Maximum input power: +30dBm(lW)  • Applicable models: HSA800 series, SAi 000 series and SA2000 series 

T/R1000 RF Demo Kit

• Radio frequency amplifier: The frequency range is 10MHz~2GHz,And the gain is 9dB~15d8(14dB@lGHz) • Radio frequency band-pass filter: Bandwidth 920MHz沉5MHz,Center frequency 922.5MHz  • Mixer: RF IN 5MHz~1500MHz             LO IN 5MHz~500MHz             RF OUT DC-1000MHz  • Oscillator LO/N:Frequency range 35MHz~4400MHz, Output power -3dBm--10dBm  •Oscillator LO:The frequency range is 2200MHz~4400MHz.,And the output power is 0dBm~+ 13dBm • Variable gain amplifier:Frequency range 15MHz~30MHz, gainrange 0dB~30dB  • Intermediate band pass filter: Bandwidth19.9MHz~22.9MHz ,Center frequency 21.4MHz • Reference timebase: 10MHz  •Interfuce:USB

FD100 frequency detection characteristic test module

• Based on BALUELEC Spectrum Analyzer, It can provide frequency discrimination   characteristic test function, Which can replace frequency scrumer  • Size 100mmx60mmx25mm • Universal USB interfuce for easy control  • Weight≤200g • Applicable models: SA1000 series and SA2000 series

DA800 directional broadband antenna

• Frequency measurement range: 600MHz-8000MHz •Input impedance: 50Ω • VSWR(Typical):<2:1 • Gain (Typical): 6dBi • Weight: 400g • Dimension: 353mrnx223mrnx28mrn

Message feedback

Welcome to leave a message online, please fill in the information according to the following form; We will contact you as soon as possible according to the information you fill in

Submit Message

Contact Us

Tel: +86-0551-68107097

Email: admin@baluelec.com

Address: No. 800, Wangjiang West Road, High-tech Zone, Hefei City, Anhui Province China.

WeChat
WeChat
Tiktok
Tiktok
Video Number
Video Number

Copyright © Baluelec

安安新材料

 Powered by: 300.cn  |  SEO   |   Business License